Yaskawa GPD 515/G5 to F7 User Manual

Page 38

Advertising
background image

Product Transition Guide
Appendix 2- Parameter Differences

____________________________
PL.F7.02.TransitionGuide 6/5/06
Page 38 of 40

Yaskawa Electric America, Inc

GPD515/G5 Parameters

F7 Parameters

Parameter

No.

Name

(DigitalOperator

Display)

Setting or Selection

Parameter

No.

Name

(Digital Operator Display)

Remarks on

Setting or Selection

O1-01

Monitor Selection
User Monitor Sel

Monitor selection
4: Control method
5: Motor speed
6: Output voltage
7: DC bus voltage
8: Output power
9: Torque reference internal
10: Input terminal status
11: Output terminal status
12: Internal Control Status 1
13: Elapsed time
14: Flash software ID number
15: External terminal 13 input voltage
16: External terminal 14 input voltage
17: External terminal 16 input voltage
18: Motor secondary current Iq
19: Motor excitation current Id
20: Primary frequency after SFS
21: Speed controller ASR input
22: Speed controller ASR output
23: Speed deviation
24: PID feedback
25: DI-16 reference
26: Voltage reference Vq output
27: Voltage reference Vd output
28: CPU ID number
32: ACR output of q axis
33: ACR output of d axis
34: First Parameter Causing an OPE
35: Zero Servo Pulse Count
36: PID Input
37: PID Output
38: PID Setpoint

Modified name:
15:Terminal A1 Input Voltage
16:Terminal A2 InputVoltage
17:Terminal A3 Input Voltage

Deleted in F7
23: Speed deviation

Added selections:
29: kWh Lo 4 Digits
30: MWh kWh Hi 5 Digits
39: Memobus Communication
Error Code Transmit Err
40:Heatsink Cooling Fan
Operation Time
41: Heatsink Temperature
44: ASR output without filter
45: Feed forward control
output




O1-05

Parameter No.
Display Selection
Address Display

0:Parameter Number
1:Memobus Address

o1-05

LCD Brightness
Adjustment

Modified function:
Sets the contrast of the digital
operator LCD. A set ting of
“1” is the lightest contrast and
a setting of “5” is the darkest
contrast.

o2-10

Cumulative CoolingFan
Operation Time Setting

New parameter

o2-12

Fault Trace/Fault
History Clear Function

New parameter
0: Disabled no effect.
1: Enabled - resets U2 and U3
monitors, and returns o2-12 to
zero.

















Advertising