Product Transition Guide

Appendix 2- Parameter Differences

____________________________

PL.G7.02.TransitionGuide 4/21/04

Page 31 of 38

Yaskawa Electric America, Inc

GPD515/G5 Parameters

G7 Parameters

Parameter

No.

Name

(DigitalOperator Display)

Setting or Selection

Parameter

No.

Name

(Digital Operator Display)

Remarks on

Setting or Selection

H4-01

Monitor Selection
Terminal 21

Analog output selection terminal
21 same as F4-01
1: Frequency reference
2: Output frequency
3: Inverter output current
5: Motor speed
6: Output voltage
7: DC bus voltage
8: Output power
9: Torque reference internal

15: External terminal 13 input
voltage
16: External terminal 14 input
voltage

17: External terminal 16 input
voltage
18: Motor secondary current Iq
19: Motor excitation current Id
20: Primary frequency after SFS
21: Speed controller ASR input
22: Speed controller ASR output
23: Speed deviation
24: PID feedback
26: Voltage reference Vq output
27: Voltage reference Vd output
31: Not Used
32: ACR q Output
33: ACR d Output
36: PID Input
37: PID Output
38: PID Reference

H4-01

H4-01Terminal FM
Monitor Selection

Terminal number renamed
15: Terminal A1 Input Level
100% = 10Vdc
16: Terminal A2 Input Level
100% = 10Vdc or 20mA
17: Terminal A3 Input Level
100% = 10Vdc






Removed:
23: Speed deviation






Additional:

42: Motor flux calculation value
43: Motor flux current compensation
44: ASR Output without filter
45: Feedforward Control Output
48: Stabalizing speed during regen

H4-02

Terminal 21
Output Gain

H4-02

Terminal FM Gain Setting

Terminal number renamed

H4-03

Terminal 21Output Bias

H4-03

Terminal FM Bias Setting Terminal number renamed

H4-04

Terminal 23 Monitor

H4-04

Terminal AM Monitor
Selection

Terminal number renamed

H4-05

Terminal 23
Output Gain

H4-05

Terminal AM Gain
Setting

Terminal number renamed

H4-06

Terminal 23
Output Bias

H4-06

Terminal AM Bias Setting Terminal number renamed

H4-07

Analog Output
Signal Selection

0: 0 - +10 VDC
1: 10V +10 VDC

H4-07

Terminal FM Signal
Level
Selection

Terminal number renamed
0: 0 - 10 Vdc
1: -10 to +10V
2: 4-20 mA*
* Set the analog output jumper CN15 in the
proper position.

H4-08

Terminal AM Signal
Level Selection

New Parameter
0: 0 - 10 Vdc
1: -10 to +10V
2: 4-20 mA*
* Set the analog output jumper CN15 in the
proper position.

H5-04

Stopping Method After
Communication Error

0: Ramp to Stop
1: Coast to Stop
2: Fast - Stop
3: Alarm Only

Additional selection:
4: Run at D1-04

H5-06

Drive Transmit Wait
Time

New parameter

H5-07

RTS Control Selection

New parameter
0: Disabled RTS is always on
1: Enabled RTS turns on only when
sending