Product Transition Guide

GPD515/G5 to G7

Main Specification Differences G5 to G7

Specification

G5 Specification

G7 Specification

Control mode

V/f, V/f w/ PG,

Open-loop vector,

Closed-loop flux vector

V/f, V/f w/ PG,

Open-loop vector, Closed-loop flux vector,

Open-loop vector 2

Inverter capacity range

460V 0.4kW to 300kW (0.5 to 400HP)
230V 0.4kW to 110kW (0.5 to 150HP)

575V 1.5kW to 160kW (2 to 200HP)

Modular: 300 to 1800HP (VT)

480V 0.4kW to 300kW (0.5 to 400HP)
240V 0.4kW to 110kW (0.5 to 150HP)

Main power circuit

configuration

2-Level 3-Level

Ra

tings

Rated output current

Example: 240V class, 3.7kW, 17.5A

Example: 240V class, 3.7kW, 18A

ASR scan time

2msec

1.25msec (except Open-loop vector 2)

CASE scan time

5msec

2.5msec (except Open-loop vector 2)

I/O Sequence Scan Time

5msec

2.5msec (except Open-loop vector 2)

Microprocessor

First generation

Second generation

Output current limit

protection

Hardware Hardware,

Software

Output frequency resolution

0.01Hz 0.001Hz

Speed control accuracy

Open-loop vector: ±0.2%,

Closed-loop flux vector: ±0.02%

Open-loop vector 2: ±0.1%,

Closed-loop flux vector: ±0.01%

Speed control range

Open-loop vector: 100:1

Open-loop vector 2: 200:1

Speed response

Open-loop vector: 5Hz

Closed-loop flux vector: 30Hz

Open-loop vector 2: 10Hz

Closed-loop flux vector: 60Hz

Starting torque

Open-loop vector: 150% at 1Hz

Open-loop vector 2: 150% at 0.3Hz

Motor surge protection

(480V)

No Yes

(3-Level)

Open loop torque control

No

Yes (Open-loop vector 2)

Torque reference scan time

2msec

1.25msec (except Open-loop vector 2)

Perfo

rman

ce F

eatu

res

Torque response

150Hz

(Closed-loop flux vector)






300Hz

(Closed-loop flux vector)