GPD515/G5 to G7


GPD515/G5 Parameters

G7 Parameters

Parameter

No.

Name

(DigitalOperator Display)

Setting or Selection

Parameter

No.

Name

(Digital Operator Display)

Remarks on

Setting or Selection

L8-17

IGBT Protection
Selection at Low
Frequency

0: Conventional
1: Lower fc
Carrier frequency is decreased
when fout 10Hz and the
load is > 100% iac.
2: Short term OL2
OL occurs after 2 seconds
during low speed
[fout 6Hz] current limit.
3: I-Limit=150%
Current limit is set to 150% of
the inverter rated current.

Deleted in G7

L8-19 OL2 Characteristic

Selection at Low Speed

0: Disabled-Low frequency OL
disabled
1: Enabled-Low frequency OL
enabled

L8-15

OL2 Characteristic
Selection at Low Speeds

Changed parameter number

L8-18

Soft CLA Selection

New parameter
0: Disabled
1: Enabled.

n3-01

High Slip Braking
Deceleration Frequency
Width

New parameter

n3-01

High slip braking decel
frequency width

New parameter

n3-02

High Slip Braking Current
Limit

New parameter

n3-03

High Slip Braking Dwell
Time at Stop

New parameter

n3-04

High Slip Braking
Overload Time

New parameter

n4-07

Observer Integral Time

New parameter

n4-08

Observer Proportional
Gain

New parameter

n4-10

Proportional Gain on Hi-
Speed Side of Observer

New parameter

n4-11

Observer Switching
Frequency

New parameter

n4-15

Lo-Speed + Regen
Stability Coefficient 1

New parameter

n4-17

Torque Adjustment Gain

New parameter

n4-18

Gain for Feeder
Resistance Adjustment

New parameter

n4-28

Observer Switching
Frequency 2

New parameter

n4-29

Torque Adjustment Gain
2

New parameter

n4-30

Low Speed + Regen
Stability Coefficient 2

New parameter

n4-32

Observer Gain
Modulation Frequency

New parameter

n4-33

Observer Gain
Modulation Frequency 2

New parameter

n4-34

Observer Gain
Modulation Rate

New parameter

n5-01

Feed Forward Control
Selection

New parameter
0:Disabled
1:Enabled

n5-02

Motor Accel Time

New parameter

n5-03

Feed Forward
Proportional Gain

New parameter