Specification g5 specification g7 specification – Yaskawa GPD 515/G5 to G7 User Manual

Page 7

Advertising
background image

Product Transition Guide

GPD515/G5 to G7

__________________________

Specification

G5 Specification

G7 Specification

I/O

Quick disconnect I/O

terminals

No Yes

Ana

log

Inputs

Programmable functions

39 45

Quantity

0-±10VDC x 2

0-±10VDC/4-20mA x 2

Type

-10-10VDC x 2
(8 bit plus sign)

-10-10VDC or 4-20mA x 2

(8 bit plus sign)

Ana

log

Outputs

Programmable functions

27 30

Quantity

8 12

Type

24VDC, NPN

Photo coupler isolation, 8mA

24VDC, sinking or sourcing (NPN/PNP)

Photo coupler isolation, 8mA

Internal or external power supply

Digital

Inputs

Programmable functions

45 51

Quantity

4 6

D

ig

it

a

l

Outputs

Type

Qty 1: Programmable: Form A,

250VAC, 1A, 30VDC, 1A

Qty 1: Dedicated Fault, Form C,

250VAC, 1A, 30VDC, 1A

Qty 2: Programmable, photo-

coupler (open collector output),
48V, 50mA, common emitter
connection

Qty 3: Programmable: Form A,

250VAC, 1A, 30VDC, 1A

Qty 1: Dedicated Fault, Form C,

250VAC, 1A, 30VDC, 1A

Qty 2: Programmable, photo-coupler

(open collector output), 48V, 50mA,
separate emitter connection

Quantity

0 1

Signal level

~

0-32kHz, low level: 0.0-0.8VDC high

level: 3.5-13.2VDC, duty cycle: 30-70%,

3kohm

P

u

ls

e

Input

Programmable functions

~ 4

Quantity

0 standard (1 with option)

1

Signal level

~

0-32kHz, 9.0VDC, 2.2kohm

Pu

lse

Output

Programmable functions

~ 6

Braking DB transistor

Built-in to G5M27P5 (10HP)

Built-in to G5M4015 (25HP)

Built-in to G7U2015 (20HP)

Built-in to G7U4015 (25HP)

S

to

p

p

in

g

Flux/High slip braking

No Yes

Modular replacement

No Yes

On/Off control

No Yes

C

o

o

li

n

g

Fa

n

Cumulative fan operation

time

No Yes

Desig

n

F

eatu

res

Auto-tuning

Rotational

Rotational

Stationary

Stationary (primary resistance only)

PL.G7.02.TransitionGuide 4/21/04

Page 7 of 38

Yaskawa Electric America, Inc

Advertising