Cooling fan fuse – Yaskawa GPD 506/P5 Section One User Manual

Page 45

Advertising
background image

PP.P5G5.01.Troubleshoot

Page 45

Rev. 06/11/2003

Cooling Fan Fuse

for models 18kw through 160kW

18kW through 160kW Yaskawa GPD 506/P5 and GPD 515/G5 inverters

have a cooling fan fuse for the 230V AC fans. The fuse is located on either
the power supply board or the tap change board (3PCB). If the cooling fan
fuse is open, then the fan(s) may be defective.

The fuse can easily be checked using an ohmmeter set to the R X 1 scale.

Place one lead of the ohmmeter on one side of the fuse, and place the other
lead of the ohmmeter on the other side of the fuse. If the fuse is bad, the
measured value will be infinite ohms.