3.3 Standard Connection

E-25

English

Configure the holding brake circuit that is to be activated upon occurrence of emergency stop.

Note: 1. AVR1: 24 VDC power supply for brake

AVR2: 24 VDC power supply for

sequence

SW1: Power OFF switch
SW2: Power ON switch
MC1: Magnetic contactor
Ry1:

Brake relay

• Parts example

Surge absorber Okaya Electric Industries Co., Ltd. CRE-50500

(Sold as: Spark Quencher)

Flywheel diode Toshiba Corporation 1NH42

Brake relay

OMRON Corporation MY series

Varistor

Nippon Chemi-Con Corporation TNR7V121K

2. The ground protection circuit is designed for ground fault inside the motor windings

while the motor is running. Therefore, it may not protect the system under the following
conditions.
• A low-resistance ground fault occurs between the main circuit cable and connector for the servomotor.
• The power supply is turned ON during a ground fault.
To configure a safer system, install an earth leakage breaker for protection against over-
loads and short-circuiting, or install an earth leakage breaker combined with a wiring cir-
cuit breaker for ground protection.

Relay Circuit Example

NOTE

SERVOPACK

0 V

Emergency Stop

5 VDC to 24 VDC