3.5 SERVOPACKs and Applicable Peripheral Devices

E-28

3.5 SERVOPACKs and Applicable Peripheral Devices

* 1. Nominal value at the rated load. The specified derating is required to select the appropriate molded-case circuit breaker.
* 2. Cut-off characteristics (25

°C): 200 % two seconds min. and 700 % 0.01 seconds min.

Note: 1. The ground protection circuit is designed for ground fault inside the motor windings while the motor is running.

Therefore, it may not protect the system under the following conditions.
• A low-resistance ground fault occurs between the main circuit cable and connector for the servomotor.
• The power supply is turned ON during a ground fault.
To configure a safer system, install an earth leakage breaker for protection against overloads and short-circuiting,
or install an earth leakage breaker combined with a wiring circuit breaker for ground protection.

2. It is recommended to use a general-purpose circuit breaker of the rated current 200 mA or more, or a circuit

breaker for inverters (for high-frequency).

3.6 Main Circuit Wiring

• SJDE SERVOPACKs are suitable where the power supply is less than 5000 Arms (230 V max.).
• SERVOPACKs must be used with UL-listed fuses or circuit breakers, in accordance with the National Electrical

Code (NEC).

• Use 75

°C heat-resistant copper wires or an equivalent.

3.7 SERVOPACK Main Circuit Wire Size

„

Cable Types

• Wire sizes are selected for three cables per bundle at 40

°C ambient temperature with the rated current.

• Use cables with a minimum withstand voltage of 600 V for main circuits.
• If cables are bundled in PVC or metal ducts, consider the reduction ratio of the allowable current.
• Use heat-resistant cables under high ambient or panel temperatures where normal vinyl cables will rapidly deteri-

orate.

• Do not use cables under continuous regenerative state.

SERVOPACK

Power

Supply

Capacity per

SERVOPACK

kVA

Current

Capacity of

Molded-case

Circuit Breaker

Arms

*1 *2

Current

Capacity and

Model of

External

Fuse

Inrush

Cur-

rent

A0-p

Magnetic

Contac-

tor

*3

Noise

Filter

Surge

Absorber

AC

Reactor

Type

Capa-

city

SJDE-
01APA-OY

100 W

0.40

4

0KLK

015.T

(15 Arms)

30

HI-11J

FN2070

-6/07

R

x

C

x

M-

601BQZ-4

X5052

SJDE-
02APA-OY

200 W

0.75

X5053

SJDE-
04APA-OY

400 W

1.2

8

FN2070

-10/07

X5054

SJDE-
08APA-OY

750 W

2.2

16

0KLK

030.T

(30 Arms)

60

HI-15J

FN2070

-16/07

X5056

Manufacturer

Littelfuse

Inc.

Yaskawa

Controls

Co., Ltd.

Schaffner

Electronic

Okaya

Electric

Industries

Co., Ltd.

(Sold as:

Surge

Protector)

Yaskawa

Controls
Co., Ltd.

Symbol

Name

Allowable Conductor Temperature

PVC

Normal vinyl cable

IV

600 V vinyl cable

60

°C

HIV

Temperature-resistant vinyl cable

75

°C