Installation environment – Yaskawa AC Drive-Option BRAKING UNIT-CDBR Spec.D User Manual

Page 20

Advertising
background image

5 Mechanical Installation

20

YASKAWA ELECTRIC TOBP C720600 01C 1000-Series Option CDBR-†D, LKEB-† Installation Manual

◆

Installation Environment

Install the CDBR Braking Unit in an environmental matching the specifications below.

■

UL and CE Compliance

Place the braking unit within an appropriate enclosure suitable to its environment for

compliance with UL and CE standards. Install unit in a pollution degree 2 environment or

equivalent according to UL standards.
For main circuit terminal wiring ( , , B1, B2), UL approval requires using UL Listed

copper wires (rated at 75

°C (167°F)).

Environment

Conditions

Installation Area

Indoors

Ambient Temperature

IP00, IP20: -10 to +50

°C (14 to +122°F)

NEMA Type 1: -10 to +40

°C (14 to +104°F)

Storage Temperature

-20 to +60

°C (-4 to +140°F) (short-term temperature during transportation)

Humidity

95% RH or less and free of condensation

Surrounding Area

Install the option in an area free from:

• oil mist and dust
• metal shavings, oil, water, or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight

Altitude

Up to 1000 m (3280 ft) without derating; up to 3000 m (9842 ft) with output and current
derating. Contact Yaskawa or your nearest sales representative for applications above
1000 m (3280 ft).

Vibration/Shock

10 to 20 Hz: 9.8 m/s

2

, 20 to 55 Hz: 5.9 m/s

2

Installation Orientation Install the option upright to maintain proper cooling.

TOBP_C720600_01C_3_0_E.fm 20 ページ 2013年10月7日 月曜日 午後2時20分