41


STEP 5

STEP 6

Lower the new belt unit into place, with the lifting bar
at the front and the drive gear towards the rear of the
printer. Locate the drive gear into the gear inside the
printer by the rear left corner of the unit, and lower
the belt unit flat inside the printer.

Turn the two fasteners (a) 90˚ to the right until they
lock. This will secure the belt unit into place. Replace
the four image drums, complete with their toner
cartridges, into the printer in the same sequence as
they came out.
Close the top cover and press down firmly at both sides
so that the cover latches closed.

Fuser Replacement

The fuser is located inside the printer just behind the four image drum units.



STEP 1

STEP 2

Press the

cover release and open the printer’s top cover

fully.

Identify the fuser handle (a). Pull the two fuser retaining
levers (b) towards the front of the printer so that they are
fully upright. Remove the new fuser from its packaging and
remove the transit material

WARNING! If the printer has recently been powered on, some fuser components will be very hot.
Handle the fuser with extreme care, holding it only by its handle, which will only be mildly warm to
touch. A warning label clearly indicates the area. If in doubt, switch the printer off and wait at least 10
minutes for the fuser to cool before opening the printer cover.