Electrical, Initialization, Safety approvals – Epson StylusPro10000 User Manual

Page 153: Initialization safety approvals

Advertising
background image

A-3

Specifications

|

A-3

Electrical

This product is also designed for IT power systems with phase to phase
voltage 220–240 V. Check the label on the back of the printer for voltage
information.

Initialization

Safety Approvals

120 V model

220/240 V model

Input voltage range

90 to 132 V

208 to 264 V

Rated frequency range

50 to 60 Hz

50 to 60 Hz

Input frequency range

49 to 61 Hz

49 to 61 Hz

Rated current

1.4 A

0.7 A

Power consumption

Approx. 130.5 W (ISO 10561 letter pattern)
29 W or less in standby mode

Hardware initialization at power on:

The printer mechanism is set to its initial state.
The input data buffer and print buffer are cleared.
The printer returns to the last default settings.

Software initialization when the ESC@ (initialize the printer)
command is received:

The print buffer is cleared.
The printer returns to the last default settings.

Panel button initialization by pressing the

Pause

button on the

control panel for 3 seconds or more:

The print head is capped.
Any paper in the printer is ejected.
The input data buffer and print buffer are cleared.
The printer returns to the last default settings.

Safety standards

UL 1950, CSA 22.2 No. 950

EMC

FCC part 15 subpart B, class A, CSA C108.8 class A

Advertising