Maintenance and service – Enviro C-10914 User Manual

Page 10

Advertising
background image

Maintenance And Service

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

F

UEL

C

ONVERSION

:

Warning: This conversion kit shall be installed by a qualified service agency in accordance

with the manufacturer’s instructions and all applicable codes and requirements

of the authority having jurisdiction. If the information in these instructions is not

followed exactly, a fire, explosion or production of carbon monoxide may result

causing property damage, personal injury or loss of life. The qualified service agency

is responsible for the proper installation of this kit. The installation is not proper or

complete until the operation of the converted appliance is checked as specified in the

manufacturer’s instructions supplied with the kit.

Please read and follow these instructions. Also, please read the instruction guidelines provided by S.I.T.

on how to remove and install the HI/LO regulator.

Step 1. Carefully inspect all parts supplied with this conversion kit.
Step 2. Shut the gas supply off at the shut-off valve. (CAUTION: The gas supply shall be shut off prior

to disconnecting the electrical power, before proceeding with the conversion.)

Step 3. Remove the glass as shown in the M

AINTENANCE

AND

S

ERVICE

- O

PENING

T

HE

D

OOR

.

Using a 1⁄2" deep

socket remove/reinstall

the main burner orifice.

Undo the two

(2) screws that

hold burner in

the firebox.

Rotate handles

and remove the

door and glass.

Lift off the pilot

head and replace

with proper pilot

orifice for fuel type

to be used.

Venturi adjustment

bracket.

Pilot assembly moved

from firebox for clarity.

Figure 9: Unit burner shown apart.

10

Step 4. Carefully remove the log

set and ember material if

they are installed.

Step 5. Remove the two (2)

screws (located on the

outside edges of the

burner) that hold the

burner to the chassis

inside the fire box, see

Figure 9. Remove the

burner tray from the

firebox.

Step 6. Change the regulator on

the front of the gas valve

(follow the instructions

provided by S.I.T.).

Step 7. To change the pilot,

simply pull the pilot hood

straight up to access the

pilot injector. Using a

5

/

32

inch Allen key, remove

the pilot injector and

replace with the proper

fuel type needed.

Advertising