Initial installation – Enviro C-10914 User Manual

Page 26

Advertising
background image

Initial Installation

QUALIFIED INSTALLERS ONLY

V

ENTING

INTO

A

C

LASS

‘A’ C

HIMNEY

:

This model is also certified and tested to vent into CLASS

‘A’ wood stove chimneys.
Place the freestanding direct vent appliance in the

desired location.
Use a conversion kit from Simpson Duravent (931, 932,

or 933), or Security Chimney (SV4CCK1, SV4CCK2, or

SV4CCK1). Which kit is used will depending on the inner

diameter of the CLASS ‘A’ chimney that this appliance is

to be vented into.
Place a bead of high temperature silicone or mil-pac at

each connection to ensure a tight seal.
NOTE: An approved 4” (10 cm) diameter flex liner must

be used in the application.
NOTE: Use Simpson Dura Vent from the top of the

appliance until this vent reaches the CLASS ‘A’ chimney.

Install the retro adapter to the top section of GS direct

vent pipe and install the flex liner to the retro adapter.
Fully line the CLASS ‘A’ chimney with a minimum 4” (10

cm) flex liner to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson

Cap adapter and securely attach the flex liner to the

adapter.
Secure the cap adapter to the CLASS ‘A’ chimney

ensuring an airtight seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE

IS NOT COVERED UNDER THE ANSI Z21.88-2002 CSA

2.33a-2002 TEST METHODS AND THE RESULTING ITS/

WH PRODUCT CERTIFICATION. THE CODE AUTHORITY

HAVING JURISDICTION MUST BE CONSULTED PRIOR

TO PROCEEDING WITH THIS INSTALLATION METHOD.

Figure 33: Assembly of Venting into a Class ‘A’

Chimney.