Initial installation – Enviro C-10914 User Manual

Page 17

Advertising
background image

17

Initial Installation

QUALIFIED INSTALLERS ONLY

H

ORIZONTAL

I

NSTALLATION

:

STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are

in the way when the venting system is attached. If this is the case, you may want to adjust the

location of the appliance.

STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the

desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented

towards the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a

bead of high temperature silicone on the male edge of the outer pipe. Push the pipe sections

completely together, then twist-lock one section clockwise approximately 1⁄4 turn, until the two

sections are fully locked. The female locking lugs will not be visible from the outside, on black

Sealant

Female

Locking

Lugs

Male

Locking

Lugs

Figure 16: Twist-Lock Connection

Woodscrews

Wall Thimble

Strap

Sheet metal

screws

Fold strap

here

1

1

/

4

"

(3.2cm)

Figure 18: Installing Decorative Wall Thimble.

10"

(254mm)

10"

(254mm)

Figure 17: Wall Framing Hole for

Horizontal Installation.

pipe. They may be located by examining the inside of the

female ends as shown in Figure 16.

Notes:
(1) Twist-lock procedure:

four

(4)

indentations,

located on the female end

of the pipes and fittings, are

designed to slide straight

onto the male ends of

adjacent pipes and fittings,

by orienting the four pipe

indentations so they match

and slide into the four entry

slots on the male end.
(2) Horizontal runs of vent

pipe must be supported

Advertising