Specifications – Enviro C-10914 User Manual

Page 5

Advertising
background image

5

Specifications

WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can

result in carbon monoxide (CO) poisoning and possible death.

D

IMENSIONS

:

16

5

/

8

"

(42.2cm)

25 3⁄4"

(65.3cm)

25 3⁄4"

(65.4cm)

27"

(68.6cm)

25 3⁄4"

(65.3cm)

17

1

/

8

"

(43.5cm)

15 3⁄4"

(40.0cm)

27"

(68.5cm)

15

1

/

8

"

(39.0cm)

Floor to center of flue

REAR VENT

231⁄2” (59.7 cm)

C

LEARANCES

TO

C

OMBUSTIBLES

:

A. Sidewall to unit

11 inches (27.9 cm)

B. Backwall to unit

2.5 inches (6.35 cm)

C. Corner to unit

2.5 inches (6.35 cm)

D. Ceiling

60 inches above floor (152.4 cm)

E. Floor

(hard wood and linoleum) 0 inches

Note: When installing on a carpeted surfaces a non-

combustible hearth pad must be used.
Minimum Alcove Dimensions:

Width

48 inches (121.9 cm)

Height

60 inches (152.4 cm)

Depth (max)

24 inches (60.96 cm)

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE

Figure 1: Westport Exterior Dimensions.

�����

���� ����

��

��

��

��

�������� ����

��

��

��

Figure 2: Clearances to combustibles.