Firebox Top

Flue Collar

Adapter

Undo four 1⁄4"

screws that

hold flue collar

elbow to unit.

Figure 34: Step 3 of Converting Top Vented into

Rear Vented.

Figure 35: Step 4 of Converting Top

Vented into Rear Vented.

I

NSTALLATION

OF

R

EAR

V

ENTED

A

PPLIANCE

:

Siding

Exterior wall

Drywall

Vent pipe

Inside finished collar

Wall thimble

Minimum vent terminal 36"

(91.4cm) high snorkel kit.

Figure 36: Installation for Rear Vented;

30,000 Btu/hr.

Initial Installation

QUALIFIED INSTALLERS ONLY

C

ONVERTING

T

OP

V

ENTED

INTO

R

EAR

V

ENTED

:

This unit has been shipped as a 30,000 Btu/hr top-vented freestanding unit. This unit can be converted

to a rear vented unit with a 36” (915 mm) snorkel for some installation applications.To convert this unit

to a rear vented model you must remove the flue pipe adapter and turn to the rear vent position. See

sections I

NITIAL

I

NSTALLATION

- I

NSTALLATION

OF

R

EAR

V

ENTED

A

PPLIANCE

.

1. Carefully remove the trivet and the stovetop. Place on a

soft surface as not to damage the porcelain finishes.

2. Remove the four (4)

1⁄4” screws that hold

the flue collar elbow

to the unit body (see

Figure 34).

3. Carefully remove the

elbow being sure

not to damage the

gasket that is glued

to the flue collar

elbow, it seals the

flue to the firebox.

4. Turn the elbow to the rear vent position and re-fasten with the

screws removed in step 2 (see Figure 35).

Place the unit into position.
Attach a small section of pipe on the unit and mark exterior wall

where vent would pass through the wall.
Cut a 10” (25.4 cm) minimum hole in the wall to maintain

clearances to combustibles. Frame hole as shown in Figure 17.
Install a wall thimble.
Install interior finished collar.
Install the vent section through the wall.
THIS UNIT MUST BE VENTED WITH A 36” (91 cm) SNORKEL KIT

IF UNIT IS RATED FOR 30,000 Btu/hr NG and 26,000 Btu/hr LP.
Seal around the vent terminal to the structure using a non

hardening mastic.

Advertising