Initial Installation

QUALIFIED INSTALLERS ONLY

I

NSTALLATION

OF

T

OP

V

ENTED

; H

ORIZONTAL

T

ERMINATION

:

Siding

Exterior wall

Drywall

Vent pipe

Inside

finished collar

Wall thimble

Termination

Figure 37: Installation for Top

Vented; Horizontal Termination.

I

NSTALLATION

OF

T

OP

V

ENTED

; V

ERTICAL

T

ERMINATION

:

Vent cap

Roof flashing

Roof

truss

Flue pipe

Insulation

gaurd

Ceiling

support

Inside

finished collar

Figure 38: Installation for Top Vented;

Vertical Termination.

This is the most common type of installation style.
Set the unit in place.
Install a minimum 24” (61 cm) vertical chimney.
Install a 90° elbow, and mark the exterior wall where the vent would

pass through.
Cut a 10” (25.4 cm) minimum hole in the wall to maintain clearances

to combustibles around vent pipe. Frame hole if as shown in Figure

17.
Install wall thimble.
Install interior finished collar
Install the vent section through the wall and then install the vent

termination.
Seal around the termination using a non hardening mastic.
CORNER INSTALLATION:
This type of installation can be used in a corner installation. If a

90° elbow is used in the horizontal plane, 36” (91.4 cm) must be

subtracted from the allowable horizontal run shown in Figure 12.

Place the unit in place.
Drop a plumb bob from the ceiling to the center point of the

flue outlet.
Cut a 10” (25.4 cm) hole in the ceiling and the roof. Refer to

Figure 23.
Install the ceiling support and insulation guard.
Install the roof flashing. Ensure that the roof flashing is

installed under the roofing material so that a watertight seal

is created.
Install the flue pipe from the top of the unit through the

roof.
Ensure that all flue pipe and unit maintain required clearances

to combustibles.
CORNER INSTALLATION:
This type of installation can be used in a corner installation.

If a 90° elbow is used in the horizontal plane, 36” (91.4 cm)

must be subtracted from the allowable horizontal run shown

in Figure 12.