Initial installation – Enviro C-10914 User Manual

Page 29

Advertising
background image

29

Initial Installation

QUALIFIED INSTALLERS ONLY

F

REESTANDING

D

RAFTHOOD

A

DAPTOR

- 50-841:

This Drafthood Adaptor is a complete assembly and is ready to fit onto your Westport in a vertical vent

application only. With the Drafthood Adaptor correctly installed and wired to the gas control valve. Your

Direct Vent Fireplace can be vented like a B-Vent Fireplace.
INSTALLATION:
WARNING:
This Freestanding Drafthood Adaptor must be fitted by a qualified service technician.
Step 1
Remove the Drafthood Adaptor from the packaging. Ensure the unit and wire harness are undamaged. If

there is damage contact your dealer, distributor, or courier company before starting this installation.
Step 2
Install the adaptor so the wires exit to the rear of the fireplace. Slide the Drafthood Adaptor over the

outlet pipe of the fireplace until the bottom of the adaptor collar stops on the top of the outlet. The

Drafthood Adaptor must be safely secured to the vent flanges with either self-tapping screws and/or high

temperature sealant.
WARNING: During the fitting of the Drafthood Adaptor, ensure that the wires are not pinched between

the adaptor and the collar and/or flue outlet. Ensure that the opening of the Drafthood Adaptor is not

blocked or obstructed.
Step 3
Being careful not to run any wiring tight across metal edges; connect them to the valve and “ON/OFF”

switch (refer to Figure 39).
Step 4
Adjust the restrictor plate to position 2.5 of 5. See the vent restrictor settings in the instruction manual.
Step 5
Adjust the embers on the burner so they don’t cover the burner ports.

WIRING DIAGRAM:
The fireplace connections

are labelled in Figure 39.

When installing the Drafthood

Adaptor onto a fireplace fitted

with an optional wall switch or

an optional thermostat, remove

one wire from the switch to

the gas valve and connect the

Drafthood Adaptor harness as

shown in Figure 30.

Optional remote

control receiver

ON / OFF / Remote

thermostat switch

Purple

Grey

Blue

Grey

Grey

Optional

Thermostat

Optional

wall switch

Valve

Drafthood adaptor

300

o

F (149

o

C)

manual reset

temperature

sensor

Figure 39: Wiring Diagram for Electrical Connection.