Kaco

Kaco - Powador

Connect the inverters to each other

Connect using a 2 wire, shielded data cable

Where to connect: Terminal strip inside the inverter

The RS485 connections on the terminal strip are each double connections so that the wiring can be con-

tinued to the next inverter.

Procedure

1.

Connect the data cable to the free terminals A and B of inverter 1.

2. Insert the other end of the cable into terminals A and B of inverter 2.

3. Connect the other inverters to each other in the same way.

4. Terminate in the last inverter.

Series 2 Powador: Set the DIP switch inside the inverter to ON and all other inverters to OFF.

5. Close inverters.

Allocate communication address

Recommendation: Continuous numbering starting with 1.

Setting: Using the inverter operating display

Procedure: Start according to the inverter's instructions

Note

The 25000xi - 33000xi Kaco inverter models are shown as 3 independent inverters in the
Solar-Log™. If, for example, such inverters are available, give them addresses 1 and 2. In the
Solar-Log™ the inverters will be shown internally as 1.1 / 1.2 - 2.1 / 2.2 etc.