Solare Datensysteme Solar-Log User Manual

Page 288

Advertising
background image

288

Varta Engion Battery System

Varta Engion Battery System

Connect the consumption meter to the Solar-Log™�

The wiring is done using a

•

RS485 or

•

S0 interface.

Assigning IP addresses

•

A static IP address has to be assigned to the battery system.

•

Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The battery system in this case has to have a free IP address in the same range (from 192.168.178.1
to 192.168.178.254).

•

Procedure: Start according to the battery system‘s instructions.

Detection via the Solar-Log

™

WEB interface

•

For the device detection on the Solar-Log

™

select „Varta“ in the

Network

section from the

Confi-

guration | Devices | Definition

menu.

•

Also select the proper interfaces for the meters as well as the inverters. Confirm the selection by
clicking on

Save

.

Detection from the Solar-Log 1200

When using the Solar-Log 1200, the detection can also be started from the display.

•

Select „Varta“ from the „Network“ interface for the detection.

•

Also select the proper interfaces for the meters as well as the inverters and then start the detec-
tion.

Advertising