22 eei – Solare Datensysteme Solar-Log User Manual

Page 77

Advertising
background image

77

EEI

EEI

22 EEI

22�1 EEI

Easy Installation

Termination

Addressing

Interface

No

No

Yes

LAN

Overview

•

Integrated interface

•

The inverter‘s IP address has to be assigned.

•

Connected using network cable (patch cable) and Ethernet router or switch

•

Installation steps

•

The inverter‘s has to be assigned a static IP address.

•

Switch off the inverters and Solar-Log™

•

Connect inverters to the Solar-Log™ (RJ45).

•

Connect the inverters to each other (RJ45).

Connect inverters to the Solar-Log™

The wiring is done using a

•

network cable (patch cable/crossover cable) and the

•

Ethernet router or switch.

Connect the inverters to each other

The inverters are connected together using

the RJ45 interface and, if needed, a router or switch.

Connection setup according to the inverter‘s instructions.

Assigning IP addresses

•

A static IP address has to be assigned to the inverter via the display.

•

Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).

•

Procedure: Start according to the inverter‘s instructions

Detection from the Solar-Log

™

•

For the detection on the Solar-Log

™

, select „Benning“ as the inverter manufacturer in the

Configu-

ration | Devices | Definition

menu from the

Network

section. Confirm the selection with

Save

.

Detection from the Solar-Log 1200

•

When using the Solar-Log 1200, the detection can also be started from the display. Select „Ben-
ning“ as the manufacturer for the inverter detection from the „network“ interface and start the
detection.