Amprobe DM-II-PLUS Power-Quality-Recorder User Manual

Page 18

Advertising
background image

16

CURRENT REC:

Push Up or Down key (F1 or F2) to point to the various currents. Push F3 (+) to
highlight and select it for voltage recording or Push F4 (-) to deselect it.
HARM. REC: (Refer to Fig.21)

To view the CURRENT HARMONICS sub-page, move Up or Down key (F1 or F2)
to point to Pg and Push F3 (+). This will only display if HARM REC is set to ON.

Push F3 (+) to highlight and select it for current recording or Push F4 (-) to deselect it.

For example, the harmonics that will be recorded in Fig.21 are Thd, 01, 03, 05, and 07.

PoWER and ENERgy settings (Refer to fig.22)

4.

Note. Selecting active /reactive power will automatically select the corresponding
active/reactive energies.
Push ENTER from the CURRENT page to view this page.

CO-GENERATION: ON or OFF (the equipment under test is able to generate energy

besides absorbing it. If ON, the instrument will record the powers and energies both
absorbed and generated. If OFF, the instrument will only record powers and energies
absorbed.)
POWER: (Refer to Fig.23)

To view the POWER sub-page, push Up and Down key to point to Pg in the
HARM. REC line and Push F3 (+).
ENERGY: (Refer to Fig.24)

To view the ENERGY sub-page, push Up and Down key to point to Pg in the
HARM. REC line and Push F3 (+).

Move the arrow to point to the power that you want to record and Push F3 (+) to

highlight it in black.

Selecting active energies will automatically select the corresponding active powers.

Reactive energies will also automatically select corresponding reactive powers.

Move the arrow to point to the energy that you want to record and Push F3 (+) to

highlight it in black.

Symbols

Description

Advised Settings

START: MANU

The recording of selected parameters will start at
00 seconds after Pushing START/STOP.

STOP: MANU

The recording can be interrupted manually by
Pushing START/STOP.

START: AUTOSTOP:
AUTO

The recording of selected values will start/be
interrupted at the set dates and times. In order to
start the recording, you must Push START/STOP to
set the instrument in Stand-by mode.

INT. PERIOD

This parameter determines how often in seconds
the values of all selected parameters will be
memorized.

15 minutes

Advertising