PLANET WFT-201 User Manual

Page 12

Advertising
background image

10

4.1.3.5 Device Configurations

This page needs to configure the Copper and Fiber Setting.

• Copper Setting: to set the Auto-Negotiation Mode, Duplex mode, Speed, Flow Control and

Link Enable setting.

• Auto-Negotiation: when set to “Auto”, it will detect the speed from other end if it will be

10Mbps or 100Mbps and will set itself to be the same speed, and when set to “Force” then
it can be only set to 100Mbps or 10Mbps.

• Duplex Mode: to set the device runs in Full Duplex mode or Half Duplex mode.

• Speed: to set the device to run in speed of 10Mbps or 100Mbps.

• Flow Control: to enable or disable to flow control of the device.

• Enable: to enable or disable the linkage of the copper (RJ45).

• Fiber Setting: to set the Duplex Mode of the Fiber to be Full duplex or Half duplex mode.

NOTE:

After configuring the system device, need to press the save
button to save the setting.

4.1.3.6 SNMP Configurations

To set the SNMP setting on MIB Browser to monitor the device.

• Get Community Name: to get the device community name (default = public).

• Set Community Name: to set the device community name (default = private).

• Trap Community Name: to authorize the device trap community name (default = public).

• Trap Host IP Address: to set the trap host IP address (same as monitoring station IP ad-

dress).

EM-WFT20xv1.indd

2004/11/5, �� 12:01

10

Advertising