Connecting to the Network

3-6 Installation

Figure 3-4 Connecting a Twisted Pair Segment to the 2G4072-52

3.

Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing 
amber, blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) 
LED is not blinking amber, perform the following steps until it is on:

a.

To view the receive and transmit activity on a group of segments, press the 
GROUP SELECT button (see 

Figure 3‐4

) to step to the group of interest (Groups 1 

through 3). Each time the button is pressed, the GROUP LED lights up in 
sequence, indicating the selected Group. Receive and transmit activity for that 
group of segments is then indicated by the RX and TX LEDs for each segment.

b. Verify that cabling is Category 5 UTP with an impedance between 85 and 

111 ohms. If the port is to operate at 100 Mbps, Category 5 cabling must be used.

c.

Verify that the device at the other end of the twisted pair segment is on and 
properly connected to the segment.

d. Verify that the RJ45 connectors on the twisted pair segment have the proper 

pinouts and check the cable for continuity. Typically, a crossover cable is used 
between hub devices. A straight‐through cable is used to connect between 
switches or hub devices and an end user (computer). Refer to 

Figure 3‐5

 and 

Figure 3‐6

 for four‐wire RJ45 connections. Refer to 

Figure 3‐7

 and 

Figure 3‐8

 for 

eight‐wire RJ45 connections.