Required Tools

B-2 Mode Switch Bank Settings and Optional Installations

Required Tools

Use the following tools to perform the procedures provided in this appendix:

Antistatic wrist strap

Phillips screwdriver

Setting the Mode Switches

Figure B‐1

 shows the locations of the mode switches and the switch settings for normal 

operation. These switches are set at the factory and rarely need to be changed.

Switch definitions and positions are as follows:

Switches 1 through 6 – For Enterasys Networks use only.

Switch 7 – Clear Persistent Data. Changing the position of this switch clears Persistent 
Data on the next power‐up of the module. All user‐entered parameters, such as the IP 
address, module names, etc., are reset to the factory default settings. Once the module 
resets, you can either use the factory default settings or reenter your own parameters.

Warning: This unit may have more than one power supply cord. Disconnect two power
supply cords before servicing to avoid electric shock.
Advertencia: Esta unida puede tener mas de un cable de fuente de poder. Desconectar
dos cables de fuentes de poder antes de dar servicio para prevenir riesgo eléctrico.
Warnhinweis: Dieses Gerät hat mehrere Netzanschlüße, trennen Sie vor den
Wartungsarbeiten beide Netzanschlüsse vom Versorgungsnetz. zum Schutz vor
elektrischen Schlägen.

Caution: An antistatic wrist strap is required to perform the procedures in this appendix.
Use the antistatic wrist strap to minimize ESD damage to the devices involved.
Precaución: Para llevar a cabo los procedimientos especificados en el apéndice deberá
utilizar una pulsera antiestática. Esta pulsera sirve para minimizar los efectos de las
descargas de electricidad estática.

Caution: Read the appropriate sections to be fully aware of the consequences when
changing switch settings.
Only qualified personnel should change switch settings.
Precaución: Si desea modificar la configuración del interruptor, lea las secciones
correspondientes para saber cuál será el resultado de hacerlo.
Estas modificaciones a la configuración sólo debe realizarlas personal calificado.