Recommended Shutdown Procedure Using RESET Button

Before shutting off power to a 2G4072‐52,

press or tap on its RESET button for less than 1 second.

Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the 2G4072‐52 is shutting down. At the end of the shutdown routine, the CPU LED 
changes to a 67%/33% sequence of amber/off, respectively, indicating the system is in a 
halt state. At this time it is safe to restart the 2G4072‐52.

When you initiate a controlled shutdown with the RESET button, you have 60 seconds 
from the time the CPU starts flashing amber/off until the device automatically restarts.

Last Resort Shutdown Procedure Using RESET Button

To reset a 2G4072‐52 without it performing an orderly shutdown routine, 

press and hold the RESET button for approximately 6 seconds.

RESET

CONSOLE

CPU

PWR

GROUP

SELECT

GROUP 3

GROUP 2

GROUP 1

Reset button

Caution: This method of shutting down a Enterasys Matrix N SA 2G4072-52 is not
recommended except as a last resort, because all processes currently running on the
module will be interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos Enterasys
Matrix N SA 2G4072-52. Recurra a él sólo como último recurso, puesto que interrumpe
todos los procesos del módulo en funcionamiento, lo que podría resultar pérdidas de
frames.

Advertising