Troubleshooting Checklist

4-4 Troubleshooting

Troubleshooting Checklist

If the 2G4072‐52 is not working properly, refer to 

Table 4‐2

 for a checklist of problems, 

possible causes, and recommended actions to resolve the problem.

Table 4-2 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

All LEDs are
OFF.

Loss of power.

Ensure the 2G4072-52 was installed properly according to
the installation instructions in

Chapter 3

, and that the

chassis has power.

No Local
Management
Password
screen.

Incorrect terminal setup.

Refer to the Enterasys Matrix N Standalone Series
Configuration Guide
for proper setup procedures.

Improper console cable pinouts.

Refer to

Appendix A

for proper COM port pinouts.

Corrupt firmware image or
hardware fault.

If possible, attempt to download the image to the
2G4072-52 again. Refer to

Appendix B

for instructions to

clear NVRAM.

Cannot navigate
beyond
Password
screen.

Improper username/ password
combination entered.

If the username/password combination has been forgotten,
refer to

Appendix B

for instructions on how to set the mode

switch to reset the username/password combination to the
default values.

Cannot contact
the 2G4072-52
through in-band
management.

IP address not assigned.

Refer to the Enterasys Matrix N Standalone Series
Configuration Guide
for the IP address assignment
procedure.

Port is disabled.

Enable port. See Enterasys Matrix N Standalone Series
Configuration Guide
for instructions to enable/disable
ports.

Host Port policy and/or
management VLAN is incorrectly
configured, or not configured.

Verify that a management VLAN exists and that it is
associated with the Host Port.
Refer to the Enterasys Matrix N Standalone Series
Configuration Guide
for information about Host Port and
management VLAN configuration.

No link to device.

Verify that all network connections between the network
management station and the 2G4072-52 are valid and
operating.
If the problem continues, contact Enterasys Networks for
technical support.