Datavideo RMC-180 Mark II PTZ Camera Controller User Manual

Page 15

Advertising
background image

15

RJ-45 ports to connect cameras to channels A, B, C & D

Four RJ-45 ports are provided on the RMC-180 MARK II rear
for connecting PTZ cameras. The interface standard is

RS-

422

and uses any RJ-45 cable to connect the RMC-180

MARK II to the RS-422 port of the Block/PTZ camera. The
cabling required needs to be custom-made and can be
made by yourself or a competent technician. See

Section 5

RS-422 Pinout

for more information.

Note: Enable RS-422 connection mode on the Block/PTZ
camera before connecting them to these channel ports.
See the corresponding user manual for instructions.

Note

:

Max allowable cable length is

300

m.

Tally Input

The RMC-180 MARK II has the ability to receive tally signals
from Datavideo Switchers such as the SE-500HD or SE-650.
Upon receiving the video switcher’s tally output signals, the
corresponding Tally LED indicator on the RMC-180 MARK II
Control Panel will be turned ON, giving the operator an
indication of which camera is currently live at the switcher
end.

The cabling required needs to be custom-made and can be
made by yourself or a competent technician. See

Section 6

Tally Port

for more information about port pinout.

Note: Set the Tally LED Mode to Tally Input when this port
is used. See

FN8. Tally LED MODE

for more information.

DC In Socket

Connect the supplied 12V 0.5A PSU to this socket. The
connection can be secured by screwing the outer fastening
ring of the DC In plug to the socket.

Power On/Off Switch

Switches the device ON / OFF.

Advertising