HP 9000 V2600 SCA User Manual

Page 138

Advertising
background image

116

Chapter 5

Configuration utilities

Configuration utilities

If the command line

[-on | -off | -check]

options are used,

xsecure

does not use the GUI interface. These options allow the user to

turn the secure mode on, off or allow the user to check the secure mode
status.

A simple button with a red or green secure mode indicator provides the
user with secure mode status information. The red indicator shows that
the secure mode process has begun. The label near the red button will
inform the user when the SSP is secure. A green indicator and the
appropriate label shows that the network is available and the SSP may
be accessed through the ethernet port.

In order for

xsecure

to work properly the SSP, console cables, terminal

mux and modems must be configured in specific ways. The SSP JTAG
connections, OBP connections and an optional terminal mux must all be
connected to the Diagnostic LAN and identified in the

/etc/hosts

file

as

tsdart-d

. The sppconsole serial cable must be connected to serial

port 1 and to node 0. An optional modem may be connected to serial port
2.