Power on detected errors, Table 15 cub detects power on error – HP 9000 V2600 SCA User Manual

Page 188

Advertising
background image

166

Appendix A

LED codes

Power on detected errors

Power on detected errors

This section describes core utilities board (CUB) LED errors from
highest to lowest priority detected at power on. The Attention LED on
the core utilities board (CUB) turns on, and the Attention light bar on
the front of the node flashes to indicate the presence of an error code
listed in Table 15. Additionally, only the highest priority error is
displayed. Once remedied, an error that is cleared may expose a lesser
priority error.

Errors are listed in sequence from the highest to lowest priority.

NOTE

Errors from LED hex code 00 through hex code 67 shut the system down,
and errors from hex-code 68 through 73 leave the system up.

Table 15

CUB detects power on error

LED

Fault

Symptoms

Corrective action

00

3.3V error
(highest
priority)

1. 5V is up 3.3V is not.
2. SSP interface will not

function.

Call the Response Center.

01

ASIC Install 0
(MIB)

1. Incorrect rotation or part in

one of the processor agent
chip (PAC) sockets.

2. Incorrect rotation or part in

one of the routing (XBAR)
attachment chip (RAC)
sockets.

Call the Response Center.

02

ASIC Install 1
(EMB)

1. Incorrect rotation or part in

one of the memory access chip
(MAC) sockets.

2. Incorrect rotation or part in

one of the toroidal access chip
(TAC) on memory board (MB).

Call the Response Center.

Advertising
This manual is related to the following products: