Configuration procedures, Upgrade jtag firmware – HP 9000 V2600 SCA User Manual

Page 97

Advertising
background image

Chapter 5

75

Configuration utilities

ts_config

Configuration procedures

The following procedures provide additional details about each
configuration action and are intended as a reference.

ts_config

automatically guides the user through the appropriate procedure when a
node is selected.

Upgrade JTAG firmware

NOTE

If the node shows “Not Configured,” do not perform this procedure.
Perform the following procedure only when the status shows “Upgrade
JTAG firmware.”

Step 1. Select the node from the list in the display panel. For example, clicking

on node 0 in the list highlights that line as shown in Figure 26.

Active

The node is configured and
answering requests on the
Diagnostic LAN.

None required. This is the desired
status.

Inactive

The SSP node configuration file
contains information about the
specified node, but the node is
not responding to requests on
the Diagnostic LAN.This status
is also shown if a node was
configured and then removed
from the SSP LAN without
being deconfigured.

Power-up the node and/or check for
a LAN connection problem. If the
node information shown is for a
node that has been removed, select
the node then select “Actions,”
“Deconfigure Node,” and click “Yes.”

Node Id
changed

The node is configured and
answering requests on the
diagnostic LAN, but the node ID
currently reported by the node
does not match the SSP
configuration information.

Select the node to obtain additional
information. If the node COP
information was changed to a
different node ID and the new node
ID is correct, select “Actions,”
“Configure Node,” then click
“Configure.” The SSP configuration
information is updated using the
new node ID.

Configuration

Status

Description

Action Required