2-8. FLOAT SWITCH

8. Strip the wire ends that were cut, as well as the wire ends on

(Continued)

the new float switch. Reconnect wires using wire nuts.

9. Replace the end panel.

10. Turn on the power supply at the breaker box.

2-9. LIGHT SWITCH

1. Remove electrical power supplied to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove control side end panel.

3. Remove the wires from the switch. Using a test instrument,

check across the terminals of the switch with the switch in the
ON position, then in the OFF position. With the switch in the
ON position the circuit should be closed. With the switch in the
OFF position the circuit should be open. If the switch checks
defective, replace by continuing with this procedure.

4. Remove nut from control panel side and remove switch.

5. Install a new switch in reverse order.

6. Replace the end panel.

7. Turn on the power supply at the breaker box.