Model HCS-2,HCW-3/HCW-5/HCW-8

2-22. CONVERSION

Connect the wire coming from the fuse in the HCW-2

(Continued)

to the L

2

screw-clamp terminal block. This should make

a total of 3 wires in this block.

By using a two-blade quick-connect adaptor, connect
the remaining wire to the neutral (N) quick-connect
terminal block.

Be sure to study enclosed marked field wiring diagram
accompanying the HCW-2.

Your wiring now should match that of a standard HCW-5.

8. Test out all systems.

9. Replace the end panels.