Henny Penny HCS-2 User Manual

Page 7

Advertising
background image

Model HCS-2,HCW-3/HCW-5/HCW-8

PROBLEM

CAUSE

CORRECTION

WATER SYSTEM

A. Water will

•

Faulty float switch

•

Check float switch per

not fill

Float Switch section

•

Faulty water control switch

•

Check water control switch
per Water Control Switch
section

•

Faulty water valve

•

Check water valve per
Water Valve section

•

Water supply has been shut

•

Check the water supply

off or disconnected

LIGHTING

A. Lights will

•

Defective fuse

•

Check per Fuse section

not turn on

•

Faulty light switch

•

Check light switch per
Light Switch section

•

No neutral supplied in field

•

Check field wiring to be sure

wiring

a true neutral has been
connected

•

Loose or defective wiring

•

Check wiring and repair and
replace if necessary

B. Not all lights on

•

Faulty light bulbs

•

Replace with recommended
bulb per Light Bulb section

•

Faulty light switch

•

Check light switch per
Light Switch section