Model HCS-2,HCW-3/HCW-5/HCW-8

2-19. RADIANT HEATER

1. Remove electrical power supplied to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove the four screws located at the bottom of the heater

housing - two on each end.

3. Remove the electrical wires from the heater. Check with an

ohmmeter across end terminals. The ohm reading should be as
follows:

HCW-3 (208 volts) ..................................

43 ohms

HCW-3 (230 volts) ..................................

53 ohms

HCW-5 lower (208 volts) ........................

43 ohms

HCW-5 lower (230 volts) ........................

53 ohms

HCW-5 upper (208 volts) ........................

108 ohms

HCW-5 upper (230 volts) ........................

132 ohms

HCW-8 lower (208 volts) ........................

22 ohms

HCW-8 lower (230 volts) ........................

26 ohms

HCW-8 upper (208 volts) ........................

54 ohms

HCW-8 upper (230 volts) ........................

66 ohms

If a heater checks defective, replace it by continuing with this
procedure.

4. Slide the brackets off the defective heater and install brackets

on new heater.

5. Install the new heater in reverse order.

6. Turn on the power at the breaker box.