Henny Penny HCS-2 User Manual
Page 24
Model HCS-2,HCW-3/HCW-5/HCW-8
2-19. RADIANT HEATER
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the four screws located at the bottom of the heater
housing - two on each end.
3. Remove the electrical wires from the heater. Check with an
ohmmeter across end terminals. The ohm reading should be as
follows:
HCW-3 (208 volts) ..................................
43 ohms
HCW-3 (230 volts) ..................................
53 ohms
HCW-5 lower (208 volts) ........................
43 ohms
HCW-5 lower (230 volts) ........................
53 ohms
HCW-5 upper (208 volts) ........................
108 ohms
HCW-5 upper (230 volts) ........................
132 ohms
HCW-8 lower (208 volts) ........................
22 ohms
HCW-8 lower (230 volts) ........................
26 ohms
HCW-8 upper (208 volts) ........................
54 ohms
HCW-8 upper (230 volts) ........................
66 ohms
If a heater checks defective, replace it by continuing with this
procedure.
4. Slide the brackets off the defective heater and install brackets
on new heater.
5. Install the new heater in reverse order.
6. Turn on the power at the breaker box.