2-14. INDICATING LIGHT

3. Cut the light wires just behind the light housing.

(Continued)

4. Squeeze the plastic retainers on the light body and push the

light through the control panel.

5. Install a new light by pushing the light through the control panel

until the light snaps securely in the panel.

6. Strip the wires and reconnect with wire nuts.

7. Replace the end panel.

8. Turn on the power supply at the breaker box.

.

2-15. THERMOMETER

1. Remove electrical power supplied to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove the control side end panel.

3. Remove the sensor bulb by removing bulb retainer and pulling

on the capillary tube.

4. Remove the nuts holding the mounting brackets on the back of

thermometer housing. Push the thermometer through the control
panel.

5. Install a new thermometer in reverse order.

6. Replace the end panel.

7. Turn on the power at the breaker box.