PROBLEM

CAUSE

CORRECTION

HEATING SECTION

A. Water will

•

Faulty contactor

•

Replace contactor per

not heat

Contactor section

•

Faulty thermostat

•

Check thermostat per
Thermostat section

•

Faulty high limit switch

•

Check high limit switch per
High Limit Switch section

B. Water will not

•

Low or improper voltage

•

Use a meter and check wall

reach desired

voltage versus data plate

temperature

•

Faulty water heating element

•

Check heating elements per
Water Heater section

•

Wiring

•

Check for loose connections
or faulty wires and correct or
replace as necessary

•

Bun pans are not over water

•

Place perforated bun pans
over water

C. Radiant heat

•

Faulty infinite regulator

•

Replace infinite regulator per

not working

Infinite Switch section

•

Faulty power switch

•

Check power switch per
Power Switch section

•

Faulty radiant heater

•

Check heater per
Radiant Heater section