Henny Penny HCS-2 User Manual

Page 27

Advertising
background image

Model HCS-2,HCW-3/HCW-5/HCW-8

2-22. CONVERSION

3. Remove four (4) nuts holding top cap.

(Continued)

4. Remove top cap.

5. Set HCW-2 in place by using same stud holes which the

top cap used.

6. Install four (4) nuts which held top cap to retain HCW-2.

7. If your HCW-3 is a three phase unit, then connect the four

wires from the HCW-2 as follows:

Connect one wire coming from the HCW-2 infinite
regulator to an empty terminal on the L

3

quick-connect

terminal block.

Connect the other wire coming from the HCW-2
infinite regulator to an empty terminal on the L

2

quick-connect terminal block.

Connect the wire which comes from the fuse in the
HCW-2 to the L

2

screw-clamp terminal block. This

should make a total of three wires in this block.

By using a two-blade quick-connect adapter, connect
the remaining wire to the neutral (N) quick-connect
terminal block.

Be sure to study enclosed marked field wiring diagram
accompanying the HCW-2.

If your HCW-3 is a single phase unit, then connect the four
wires from the HCW-2 as follows:

By using a two-blade quick-connect adapter, connect
one wire from the HCW-2 infinite regulator to the L

1

quick-connect terminal block.

Connect the other wire coming from the HCW-2 infinite
regulator to the empty terminal on the L

2

quick-connect

terminal block.

103

2-19

Step 3