2-22. CONVERSION
3. Remove four (4) nuts holding top cap.
(Continued)
4. Remove top cap.
5. Set HCW-2 in place by using same stud holes which the
top cap used.
6. Install four (4) nuts which held top cap to retain HCW-2.
7. If your HCW-3 is a three phase unit, then connect the four
wires from the HCW-2 as follows:
•
Connect one wire coming from the HCW-2 infinite
regulator to an empty terminal on the L
3
quick-connect
terminal block.
•
Connect the other wire coming from the HCW-2
infinite regulator to an empty terminal on the L
2
quick-connect terminal block.
•
Connect the wire which comes from the fuse in the
HCW-2 to the L
2
screw-clamp terminal block. This
should make a total of three wires in this block.
•
By using a two-blade quick-connect adapter, connect
the remaining wire to the neutral (N) quick-connect
terminal block.
•
Be sure to study enclosed marked field wiring diagram
accompanying the HCW-2.
If your HCW-3 is a single phase unit, then connect the four
wires from the HCW-2 as follows:
•
By using a two-blade quick-connect adapter, connect
one wire from the HCW-2 infinite regulator to the L
1
quick-connect terminal block.
•
Connect the other wire coming from the HCW-2 infinite
regulator to the empty terminal on the L
2
quick-connect
terminal block.
103
2-19
Step 3