Model HCS-2,HCW-3/HCW-5/HCW-8

2-11. WATER CONTROL

1. Remove electrical power supplied to the cabinet.

SWITCH

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove the control side end panel.

3. Remove the electrical wires from the switch. Using a test

instrument, check across the terminals of the switch with the
switch in the AUTOMATIC and MANUAL position; then in
the OFF position. With the switch in the AUTOMATIC or
MANUAL position, the circuit should be closed. With the
switch in the 0 or OFF position, the circuit should be open. If
the switch checks defective, replace by continuing with this
procedure.

4. Remove the nut and guard from the control panel side of the

switch and remove the switch.

5. Install a new switch in reverse order.

6. Replace end panel.

7. Turn on the power supply at the breaker box.

2-12. INFINITE SWITCH

1. Remove electrical power supplied to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Remove the control side end panel.