Model HCS-2,HCW-3/HCW-5/HCW-8

PROBLEM

CAUSE

CORRECTION

THERMOMETER

A. Reading does

•

Thermometer bulb is not in

•

Insert bulb in block

not match

holding block

actual
temperature

•

Faulty thermometer

•

Replace per Thermometer
section

OPERATIONS

A. Product not

•

Doors are not kept closed

•

Keep doors closed when

holding

possible

temperature

•

Product held too long

•

Only hold product for
recommended times

•

Water temperature too low

•

Check water heating system
per Water Pan Heater section

•

Radiant heat too low

•

Turn to higher setting

•

Radiant heat not working

•

Check radiant heat system per
Radiant Heater section

•

Light bulbs out

•

Replace as required, per
Light Bulb section

B. Doors are

•

Doors left open too much

•

Keep doors closed when

fogging

allowing doors to cool and

possible

cause condensation

•

Radiant heat not high enough

•

Turn to higher setting

•

Radiant heat not working

•

Check radiant heater per
Radiant Heater section

•

Water temperature too high

•

See recommended settings
and temperatures

1-2

103