Model HCS-2,HCW-3/HCW-5/HCW-8

PROBLEM

CAUSE

CORRECTION

THERMOMETER

A. Reading does

Thermometer bulb is not in

Insert bulb in block

not match

holding block

actual
temperature

Faulty thermometer

Replace per Thermometer
section

OPERATIONS

A. Product not

Doors are not kept closed

Keep doors closed when

holding

possible

temperature

Product held too long

Only hold product for
recommended times

Water temperature too low

Check water heating system
per Water Pan Heater section

Radiant heat too low

Turn to higher setting

Radiant heat not working

Check radiant heat system per
Radiant Heater section

Light bulbs out

Replace as required, per
Light Bulb section

B. Doors are

Doors left open too much

Keep doors closed when

fogging

allowing doors to cool and

possible

cause condensation

Radiant heat not high enough

Turn to higher setting

Radiant heat not working

Check radiant heater per
Radiant Heater section

Water temperature too high

See recommended settings
and temperatures

1-2

103