Chapter 4 WIRING AND CONNECTION

4.2 Function Explanation of the Terminals

Terminal Code

Function

Common

terminal

electrical

specifications

Pulse train position

command inputs

SAP

SAN

SBP

SBN

Pulse train position command input (see page 16)
• Mode 0 : 90 degree phase difference pulse
(quadrature)
• Mode 1 : Forward/Reverse signal; pulse train
• Mode 2 : Forward pulse/Reverse pulse
Built-in 150 ohm termination resistance can be
turned ON or OFF with DIP switch SWR.
Mode is selected via the pulse mode selection
parameter (P013)

DC 5V receiver input
(based on RS-422
standard)

Encoder signal

inputs

EAP

EAN

EBP

EBN

EZP

EZN

A, B, Z: rotary encoder signal input

Photo coupler input
(Compatible with the
DC5V line driver
type rotary encoder)

Pulse train position

command input

permissive signal

(Note 1)

STAT

Position control with pulse train input
is valid when STAT is Turned ON.
(Note 3)

Orientation signal:

(Note 1)

ORT

Turn ON for orientation operation.
(Note 3)

LAD cancel signal:

(Note 1)

LAC

Turn ON to cancel LAD.
(Note 3)

In

pu

t termin

als

Position deviation

clear signal:

(Note 1)

PCLR

Turn ON to clear position deviation
counter. (Note 3)

CM1

Photo coupler input
(Configure to an
inverter intelligent
input terminal.)

Encoder signal

output

AP

AN

BP

BN

Retransmits the input encoder signal (ratio 1:1).

DC5V line driver
output (based on
RS-422 standard)

Power supply for

encoder

EP5

DC +5V power supply

EG5

150mA max

Positioning

completion signal

(Note 2)

POK

Used for position control or
orientation.
Output ON when the position comes
within the specified range (P017).
(Note 3)

Speed deviation

excessive signal

(Note 2)

DSE

Output ON when the real rotation
speed deviation from command speed
exceeds (P027). (Note 3)

Ou

tpu

t termin

als

Zero speed signal

(note 2)

ZS

Output when the real rotation speed
becomes zero speed detection level
(C063). (Note 3)

CM2

Open collector
outputs
(Configure to an
inverter intelligent
output terminal)

(Note 1): Valid when LAC is assigned to an intelligent input terminal of the inverter (SJ300).
(Note 2): Valid when POK is assigned to an intelligent output terminal of the main body (SJ300).
(Note 3): Refer to the configuration setting procedure for the inverter in the SJ300 Instruction Manual