Chapter 6

OPERATION


(Note 6) : If satisfactory performance can not be obtained, adjust the motor constants for the

particular symptoms observed according to following table:

Inverter
Status

Symptom Observed

Adjustment Guidelines

Parameter(s)

to Adjust

At starting

Shock occurs at
starting

Set “Motor constant J” higher gradually, up to
1.2 times the initially preset (default) value.

H024/H034

Set the speed response lower.

H005

At
deceleratio
n

Instability of motor
rotation

Set “Motor constant J” smaller than the
initially preset value.

H024/H034

During
torque limit

Insufficient torque
during torque limit
at low speed

Set overload restriction level lower than the
torque limit level(s).

b022
b041-b044

At low
frequency
operation

Irregular rotation

Set “Motor constant J” higher than the initial
preset (default) value.

H024/H034