Chapter 7 FUNCTIONS

A044: 1

st

Control Method

P052: 1

st

Proportional gain

7.4 Speed control (P/PI) switching function

Relation

Speed control mode is normally controlled by
proportional-integration compensation (Pi), which keeps the
deviation between the actual speed and speed command
becomes 0. Further, you can also achieve a propotional control
function, which can be used as drooping operation (i.e. one load
with several inverters) with this option card.
Set P/PI switching function to one of the intelligent input terminal 1

∼8 by the operator to achieve

this function. (Input ‘43’ in one of C001

∼C008.) When this is turned on, control mode becomes

proportion control (P).
Please set proportional gain(Kpp ; a value used to decide the speed change rate) to H052 by a
digital operator. The relationship between the Kpp value and the speed change rate is shown
below.

(%)

)

Value

Set

Kpp

(

10

=

)

Rate

Change

Speed

(

Relationship between Kpp Value and Speed Change Rate

0

Rotation Speed

Torque

100 %

PI control

P control

(A)












Figure 7-6 Torque characteristic (P/PI)


( )

frequency

base

speed

s

Synchronou

A

Torque

Rated

at

Error

Speed

=

)

Rate

Change

Speed

(

Relationship between Speed Change Rate and Rated Rotation Speed