2 speed control (asr), 1 function outline, 2 control mode setting – Hitachi SJ-FB User Manual

Page 26

Advertising
background image

26

Chapter 7 FUNCTIONS


Data setting of the input-output terminal

Input-output terminal

Terminal assignment

Contents

In

pu

t

ORT terminal (ORT)

Set up 45 to one of

them of C001

∼C008

ON : Orientation mode

O

ut

pu

t

Positioning

completion signal

(POK)

Set up 23 to one of

them of C021

∼C025

Output when it comes to the positioning
completion range.

7.2 Speed control (ASR)

A044: 1

st

Control method

P012: Control mode selection

A001: Frequency command selection

A002: Operation command selection

F001: Frequency setting

F002: Acceleration time

F003: Deceleration time

F004: Operation direction selection

H002/H202-H052/H252:

Motor constant relation data

When the control mode selection (P012) is set to 00, operation mode
becomes a speed control operation mode (ASR mode).

Relation

Please drive after setting up the frequency, operation command and
each motor constant .

7.3 Position control (APR)
(Electronic gear function)

When the control mode selection (P012) is set to 01, operation
mode becomes a speed control operation mode (APR mode).

7.3.1 Function outline

A044: 1

st

Control method

P012: Control mode selection

A002: Operation command selection

P017: Completion range setting

P018: Completion delay time

P019: Electronic gear position selection

P020: Electronic gear ratio numerator

P021: Electronic gear ratio denominator

P022: Feed forward gain

P023: Position loop gain

C001-C008: Intelligent input terminal

C021-C025: Intelligent output terminal

H002/H202-H052/H252:

Motor constant relation data

This function generates the frequency based on the position
command pulse which comes from the pulse train input from the
terminal and position feed back pulse which is detected by the motor
encoder, and performs the position control operation. It can be used
as synchronous operation of main and sub motor. Also the turn
ratio of main and sub motor can be changed by setting up the
electronic gear ratio (N/D). (Electronic gear function)

Relation

7.3.2 Control mode setting

Inverter at the main motor (master inverter) can be set both as a
speed control and position control. Please set up the inverter at the
sub motor side (slave inverter) to a position control mode.