Hitachi SJ-FB User Manual

Page 28

Advertising
background image

28

Chapter 7 FUNCTIONS


(Note 3) : N/D must be given as the ranges of 1/50

≤ (N/D) ≤ 20.

(N: Electronic gear ratio numerator, D: Electronic gear ratio denominator)
(Note 4) : It depends on what type of main body combines with the SJ-FB, the setting
value conversion is different. Please refer to the (Note 3) of the “5.3 Items
regarding the feed back board of the inverter main body“.
Data setting of input-output terminals

Input-output terminal

With terminal assignment

Contents

Inp

ut

The pulse train position

command input

permission signal.

(STAT)

Set ‘48’ to one of

C001

∼C008

Pulse train position command

input is valid while ON.

Outp

ut

Positioning completion

signal.(POK)

Set ‘23’ to one of

C021

∼C025

Output when it entered into the

positioning completion range


Set ‘48’ (the pulse train position command input permission signal (STAT)) to one of
C001

∼C008. Pulse train position command input is valid only in the case that the STAT terminal

is turned ON. In the case that the STAT terminal is OFF or unestablished, pulse train position
command input is invalid.

Below the example of the proportion of the slave side turn number to the master side turn number
by the setting of P019

~P021 is shown. (Yet, the encoder pulse number of the master side and

slave side are same and be in the case of 1024 pulses. )

Position selection for electronic gear (P019)

01

(REF)

01

(REF)

00 (FB)

00 (FB)

Numerator of ration setting for electronic gear
(P020)

1024 2048 1024 2048

Denominator of ratio setting for electronic gear
(P021)

2048 1024 2048 1024

Slave side turn number to the master side turn
number

1/2 2 2 1/2