2 data setting – Hitachi SJ-FB User Manual

Page 25

Advertising
background image

25

Chapter 7 FUNCTIONS



7.1.2 Data setting

Data setting related to speed control

Setting item

Function code

Setting Range, Setting Contents

Orientation speed setting (Note 1)

P015

0.00

∼99.99 / 100.0∼120.0 (Hz)

Orientation direction setting (Note 2)

P016

0:Forward / 1:Reverse

(Note 1) : In order to stop the motor for setting position. (Motor takes 2 rotation to stop setting

position)Don’t set high frequency to the orientation speed setting. Otherwise it will be
over-voltage protection trip.

(Note 2) : Turn direction of the motor while orientation is done based on the setting of P016.
Data setting related to position control

Setting item

Function

code

Setting range, setting contents

Orientation stop position(Note 3)

P014

0.

∼4095.

Completion range setting

P017

0

∼9999. / 1000 (10,000) (pulses)

(Setting four times fairly of the encoder pulses)

Completion delay time (Note 4)

P018

0.00

∼9.99

Position loop gain(Note 5)

P023

0.00

∼99.99 / 100.0 (rad/s)

(Note 3) : The orientation stop position is to be set as 4096 of division (0

∼4095) per 1 turn toward

forward from the original point. (It is 4096 division irrespective of the pulse number
of the encoder.) The original point is where the pulse has input to EZP-EZN.
Stoppage goal position is like shown in Figure 7-2 irrespective of the turn direction.

(Note 4) : It depends on what type of main body combines with the SJ-FB, the setting value

conversion is different. Please refer to the (Note 3) of the “5.3 Items regarding the
feed back board of the inverter main body“.

(Note 5) : To improve the positioning accuracy. Increase position loop gain (G).

When the motor is unstable. Decrease position loop gain.

Z pulse Position

0

1024

2048

3072

(Reference point)

Motor Shaft viewed from
the load side


Figure 7-2 Concept of Orientation setting Position

Advertising