Interface

5-72 C141-E203-01EN

Host

Reg. HD

PIO Setup

PIO Setup

PIO Setup

Data (1sector)

Data

(4 sectors)

Device

Data

(4 sectors)

Block

Block

Partial
Block

Figure 5.9 Execution example of READ MULTIPLE command

Error reporting conditions

(1) A specified address exceeds the range where read operations are allowed

(ST = 51h, ER = 10h).

(2) The range where read operations are allowed will be exceeded by an address

during a read operation (ST = 51h, ER = 10h).

(3) An uncorrectable disk read error occurred (ST = 51h, ER = 40h).

(4) The sync byte indicating the beginning of a sector was not found

(ST = 51h, ER = 01h).

(5) The READ MULTIPLE command is disabled (ST = 51h, ER = 04h).

(6) A SATA communication error occurred (ST = 51h, ER = 0Ch).

(7) An error other than the above errors occurred (ST = 51h, ER = 04h).