5.3 Host Commands

C141-E203-01EN 5-79

At command issuance (Shadow Block Registers setting contents)

CM

1 1 0 0 1 0 0 R

DH

x

L

x

x

HD No. / LBA

CH

CL

SN

SC

FR

Start cylinder No. [MSB] / LBA

Start cylinder No. [LSB] / LBA

Start sector No.

/ LBA [LSB]

Transfer sector count

xx


At command completion (Shadow Block Registers contents to be read)

ST Status

information

DH

x

L

x

x

HD No. / LBA

CH

CL

SN

SC

ER

Start cylinder No. [MSB] / LBA

Start cylinder No. [LSB] / LBA

Start sector No.

/ LBA [LSB]

00 (*1)

Error information

*1 If the command is terminated due to an error, the remaining number

of sectors of which data was not transferred is set in this register.