5.3 Host Commands

C141-E203-01EN 5-133

(49) READ VERIFY SECTOR (S) EXT (X’42’)

Description

This command is the extended command of the READ VERIFY SECTOR (S)
command. The LBA specification is increased from 28 bits to 48 bits, and the
maximum number of sectors that can be transferred by a single command is
changed from 100h to 10000h. Other command controls are the same as those of
the READ VERIFY SECTOR (S) command.

Error reporting conditions

(1) The command was issued in CHS mode (ST = 51h, ER = 04h).

The other error reporting conditions are the same as those of the READ
VERIFY SECTOR(S) command.

At command issuance (Shadow Block Registers setting contents)

CM

0 1 0 0 0 0 1 0

DH

1 L 1 x

xx

CH EXP

CH

CL EXP

CL

SN EXP

SN

SC EXP

SC

FR EXP

FR

LBA (47-40)

LBA (23-16)

LBA (39-32)

LBA (15-8)

LBA (31-24)

LBA (7-0)

Sector count (15-8)

Sector count (7-0)

xx

xx


At command completion (Shadow Block Registers contents to be read)

ST Status

information

DH

1 L 1 x

xx

CH EXP

CH

CL EXP

CL

SN EXP

SN

SC EXP

SC

ER

LBA (47-40)

LBA (23-16)

LBA (39-32)

LBA (15-8)

LBA (31-24)

LBA (7-0)

xx

xx

Error information