FUJITSU MHT2060BH User Manual

Page 171

Advertising
background image

5.3 Host Commands

C141-E203-01EN 5-97

(30) SET FEATURES (X’EF’)

The host system issues the SET FEATURES command to set parameters in the
Features field for the purpose of changing the device features to be executed.

Upon receipt of this command, the device sets the parameters in the Features field,
then reports the status to the host system.

If the value in the Features field is not supported or it is invalid, the device posts an
ABORTED COMMAND error.

Table 5.25 lists the available values and operational modes that may be set in the
Features field.

Table 5.25 Features field values and settable modes (1/2)

Features

Field

Drive operation mode

X ' 02 '

Enables the write cache function.

X ' 03 '

Set the data transfer mode.

*1

X ' 04 '

Enables the automatic reassign. (Note)

X ' 05 '

Enables the advanced power management function.

*2

X ' 06 '

Enables the Power-Up In Standby function. (Note)

X ' 07 '

Spin up the Power-Up In Standby status device. (Note)

X ' 10 '

Enables the Serial ATA function.

*3

X ' 33 '

Undefined (Note)

X ' 42 '

Enables the Acoustic management function.

*4

X ' 54 '

Undefined (Note)

X ' 55 '

Disables the read cache function.

X ' 66 '

Disables the reverting to power-on default settings after software reset. (Note)

X ' 77 '

Undefined (Note)

X ' 81 '

Prohibit the 8-bit data transfer. (Note)

X ' 82 '

Disables the write cache function.

X ' 84 '

Enables the automatic shift. (Note)

X ' 85 '

Set the advanced power management mode to Mode-0.

X ' 86’

Prohibit the Power-Up In Standby function. (Note)

X ' 88’

Undefined (Note)

X ' 90’

Disables the Serial ATA function.

Advertising
This manual is related to the following products: